太陽熱温水器パイプラインの不凍液と保温は、自己-温度制限電気加熱ケーブルを採用しています。 始動電流が小さく、加熱速度が速く、設置が簡単で、-自由に使用できるという利点があります。 これは、エネルギーを節約し、環境に優しい製品です-。
ユーザーが太陽光電気暖房ケーブルを購入するとき、それをどのようにインストールしますか? どのインストール方法を選択するのが最適ですか? それはユーザーにとって本当に難しいことです。 実際、太陽光電気暖房ケーブルの設置は非常に簡単で、以下の設置の基本事項を習得していれば、ユーザーが自分で設置することができます。
インストール方法
1. If the diameter of the water heater pipe is greater than 3 cm, the winding installation method shall be adopted. Attach the solar electric heating cable to the pipeline, and wrap it in parallel at equal distances. Pay attention to keep the electric heating cable as flat as possible without any discount. And fix it with aluminum foil tape or pressure-sensitive tape, and then cover it with a sealing and waterproof insulation layer.
2. The diameter of the water heater pipe is less than 3 cm (including 3 cm), and the single parallel installation method is adopted. Attach the solar electric heating cable to the pipeline and lay it in parallel without leaving any gap between the electric heating cable and the pipeline, and fix it with pressure-sensitive tape or aluminum foil tape, and then put on a better waterproof insulation layer.
断熱パイプライン
1. The water supply pipeline of the solar water heater and the water supply pipeline are cold water to prevent the sub-zero temperature from causing the pipeline to freeze or burst;
2. The heated downspout pipe is hot water, which can maintain the temperature of the hot water, supplement the lost heat, and prevent the pipe from freezing and cracking;


予防
1. Do not make the electric heating cable folded or overlapped to prevent short-circuit fire and poor thermal insulation effect.
2. There is no gap between the electric heating cable and the pipeline, and the thermal insulation effect is better.
3. The junction box at the end of the electric heating cable (terminal junction box) has good sealing performance, and the end of the installation end should be placed outdoors;
4. The maximum length of the solar electric heating cable is 50 meters, and it should be installed as much as possible. When the heating cable and the heating cable need to be connected and installed, an intermediate junction box can be used, and the sealing should be done to prevent the junction box from entering the water.
5. Install leakage protection switch or air switch.
6. Please consult a technician before installation, or install under the guidance of a technician.